REB Research Membrane Reactors

COMPACT MEMBRANE REACTORS, HYDROGEN GENERATORS

Can be used as a hydrogen purifier for dirty or coking gases. More usually it is filled with catalyst and used as a hydrogen generator to produce ultrapure hydrogen by one-step steam reforming of methanol or methane, or by ammonia cracking. Please see our selection of ground, sieved catalysts, including methanol or natural gas reformer catalysts and water-gas-shift catalysts.



Standard Temperature Reactors: for operation between 200 C and 450 C; Maximum pressure: 300 psi at 350 C; Selectivity to hydrogen: 100%.

Four tube reactor: 5/8" diameter by 9" tall, contains 4 membrane tubes .079" diameter by 7" tall. Typical hydrogen output: about1 std. 1/min. $4600.

Seven tube reactor: 5/8" diameter by 10" tall; contains seven membrane tubes .079" diameter by 7" tall. Typical hydrogen output: about 2 std. 1/min. $6250.

Ten tube reactor: 3/4" diameter by 12" tall; contains ten membrane tubes .079" diameter by 7" tall. Typical hydrogen output: about 3 std. 1/min. $7950.  

Microreactor for catalyst evaluation: 1/4" diameter by 2" tall; contains one membrane tube .079" diameter by 1.1" tall. Designed to test .75 to 1 cc of catalyst. Typical hydrogen output: 50 sccm. $2600.  

High Temperature Reactors: Inconel construction for operation between 200 C and 700 C; Maximum pressure: 350 psi at 400 C; Selectivity to hydrogen: 100%.

5/8" diam. by 10" tall, inconel construction; contains four high temperature membrane tubes .125" diam by 7" tall. Typical hydrogen output: about 1 std. l/min. $5400

3/4" diam. by 10" tall, inconel construction; contains seven high temperature membrane tubes .125" diam by 7" tall. Typical hydrogen output: about 2 std. l/min. $7350

1" diam. by 12" tall, inconel construction; contains ten high temperature membrane tubes .125" diam by 8" tall. Typical hydrogen output: about 3 std. l/min. $9750

One Tube Reactor (short membrane)
1/2" diam. by 20" tall, inconel construction; contains one high temperature membrane tube .125" diam by 1.1" tall. Designed to test .75 to 1 cc of catalyst. Typical hydrogen output: about 50 sccm. $3150

One Tube Reactor (long membrane)
1/2" diam. by 20" tall, inconel construction; contains one high temperature membrane tube .125" diam by 7" tall. Typical hydrogen output: about 300 scc/min. $3500

two membrane reactors

membrane reactor exploded diagram

Check out our tube furnaces as well our selection of ground, sieved catalysts. For a more turnkey hydrogen-production solution, consider our Me100 hydrogen generator. The Me100 hydrogen generator combines a methanol-water tank, a catalyst-filled, membrane reactors, a pump, a heater, a temperature controller, and pressure regulator -- working together to produce low-cost, 100% pure hydrogen on demand.

To see a membrane reactor flow diagram, plus experimental data on the use of these membrane reactors with fuel cells, click here. For specialty reactors, or consulting, please contact us.